How does capillary gel electrophoresis work




















CEC is similar to CZE in that they both have a plug-type flow compared to the pumped parabolic flow that increases band broadening.

CIEF is a technique commonly used to separate peptides and proteins. These molecules are called zwitterionic compounds because they contain both positive and negative charges. The charge depends on the functional groups attached to the main chain and the surrounding pH of the environment. In addition, each molecule has a specific isoelectric point pI. When the surrounding pH is equal to this pI, the molecule carries no net charge.

To be clear, it is not the pH value where a protein has all bases deprotonated and all acids protonated, but rather the value where positive and negative charges cancel out to zero. At a pH below the pI, the molecule is positive, and then negative when the pH is above the pI. Because the charge changes with pH, a pH gradient can be used to separate molecules in a mixture. The anodic end of the capillary sits in acidic solution low pH , while the cathodic end sits in basic solution high pH.

An amino acid with n ionizable groups with their respective pKa values pK 1 , pK 2 , Most proteins have many ionizable sidechains in addition to their amino- and carboxy- terminal groups. The pI is different for each protein and it can be theoretically calculated according to the Henderson-Hasselbalch approximation, if we know amino acids composition of protein. The proteins of a cell lysate are applied to a pH immobilized gradient strip, upon electrophoresis the proteins migrate to their pI within the strip.

CITP is the only method to be used in a discontinuous system. The analyte migrates in consecutive zones and each zone length can be measured to find the quantity of sample present. Instrumental Setup A typical capillary electrophoresis system consists of a high-voltage power supply, a sample introduction system, a capillary tube, a detector and an output device. Theory Electrophoretic Mobility Electrophoresis is the process in which sample ions move under the influence of an applied voltage.

Electroosmotic Flow The electroosmotic flow EOF is caused by applying high-voltage to an electrolyte-filled capillary. Capillary Electrochromatography CEC The separation mechanism is a packed column similar to chromatography.

HPLC is more thoroughly developed and has many mobile and stationary phases that can be implemented. HPLC has such a wide variety of column lengths and packing, whereas CE is limited to thin capillaries.

Both techniques use similar modes of detection. Can be used complementary to one another. Access enabled via: An Institution. PDF Full text Related articles. Abstract There is a great deal of interest in analytical biochemistry in the separation and identification of biologically important polymers, such as DNA protein and complex carbohydrate molecules 1,2. Related articles Based on techniques.

Ulfelder , , Springer Protocols. Jong et al. See more. Donlon et al. Tebbe et al. References Landers, J. Li, S. The capillary is first etched with KOH solution and rinsed with water. After drying, a solution of trimethoxysilne is pumped in and the unbound region is flushed away.

By another reaction carried out, an epoxide group is opened with a solution of PEG and boron trifluoride. Then the capilleries are rinsed with DI water.

This process will help decrease a significant amount of adsorption. Therefore, the separation of nucleic acids and proteins has been very common through this method. Some of the groundbreaking research in molecular biology in the past decades took advantage of the capillary gel electrophoresis method.

CGE was used in the human genome project, employing a physical gel, after a long period of frustrations with chemical hydrogels. The stability problems of the cross-linked polyacrylamide gels were halting the application of this separation method to DNA sequencing. If CGE were to be used in sequencing the human genome, the polymer matrix in the separation capillary had to be replenished in an automated system.

Thus, the human genome project used replaceable linear polymer matrices for automated large-scale DNA sequencing 5. For the separation of proteins, their properties must be taken into account. While different proteins vary in size; they also vary in charge. In order to separate proteins based on size in CGE, proteins are treated with a detergent SDS that allows their native charge to be masked.

Since SDS molecules are highly negatively charged, the native charge of the proteins can be masked. The biotechnology industry uses CGE method for separation analysis of biomaterials on a routine basis with microchips. Contact us. Aggregate analytics — Overview. Asymmetrical flow field-flow fractionation AF4.

Dynamic light scattering DLS. Hollow fiber flow field-flow fractionation HF5.



0コメント

  • 1000 / 1000